The mobile flare systems offer high availability and safe operation. They are available in various capacity classes up to 12 MW thermal and offer numerous advantages:
- Compact design and high specific output
- Minimal installation effort and short commissioning time
- Low maintenance and servicing requirements
- Input pressures from 50 mbar to 100 bar possible with corresponding gas pressure control sections
- Constant output across the entire pressure range
- Thermal treatment of purge gases with low calorific value
- Modern control technology with optional remote monitoring
Technical specifications:
|
Characteristic |
MGF 0.5 |
MGF 3.0 |
MGF 12.0 |
|
Thermal load range (kWth) |
250 – 500 |
1,500 – 3,000 |
3,000 – 12,000 |
|
Max. gas flow rate (Nm³/h) |
50 |
300 |
1,200 |
|
Required inlet pressure (mbar) |
100 |
100 |
100 |
|
Combustion temperature (°C) |
1,000 – 1,200 |
1,000 – 1,200 |
1,000 – 1,200 |
|
Power supply |
CEE 16 A |
CEE 32 A |
CEE 63 A |
|
Transport |
Car trailer (< 2,500 kg) |
Car trailer (< 3,200 kg) |
Project-specific |